ratings

   

946

RX7s Metal Lampholder

Distance of mounting surface = length of lamp + 17 mm
rated voltage: 1000 V
rated current: 20 A
rated temperature: T350
category: II
ignition voltage: 5 kV
shock protection: enclosed
insulation: basic insulation

   

946

RX7s Metal Lampholder

Distance of mounting surface = length of lamp + 65 mm
rated voltage: 1000 V
rated current: 20 A
rated temperature: T350
category: II
ignition voltage: 5 kV
shock protection: enclosed
insulation: basic insulation

   

939

RX7s Ceramic Lampholder

Distance of mounting holes =
length of lamp + 4 mm
or lamplength + 26.5 mm
rated voltage: 1000 V
rated current: 10 A
rated temperature: T250
category: III
ignition voltage: 15 kV
shock protection: enclosed
insulation: basic insulation